1. Introduction
The Safe-t-FLEX Heating ElementThe principle of Safe-t-FLEX heating elements is based on a continuous resistive sheet providing heat evenly over the black surface areas. Safe-t-FLEX consists of a specially formulated semi-conductive medium, coated onto polyester film or impregnated into glass cloth. Power is fed to this resistive coating by way of copper electrodes that are fixed to the longitudinal edges of the heating areas This structure is insulated by a lamination of polyester based films that totally cover the element and is wider than the conductive heating area, forming strong clear edges that are designed to accept subsequent stapling to sub floor surfaces. Low temperature Safe-t-FLEX floor heating elements produce a gentle heat that evenly warms the whole room. Once the surfaces have been warmed, the heat is reflected resulting in comfortable, natural warmth with minimum floor to ceiling temperature variation. Note: This installation guide is available in more detail in pdf format in our Downloads section. 2. Installation ProcedureBefore commencement of installation always check on the following:
3. Equipment required for installation
In addition to the above, the following will also be required: Thermal insulation, personal protection equipment, tape measure, suitable marker pen, scissors or knife, straight edge, additional cable ties, test equipment and other electrical items; where necessary suitable ancillary lighting for working in dark areas etc. Note: Electrical test equipment and crimp tools must be regularly calibrated. 4. Basic Technical DataElement wattage densities are 135 W/m2. Thickness 0.5 mm. Wattage rates are 49.95 watts per linear meter for 370/400 and 67.5 watts per linear meter for 500/530. Rolls 530 mm wide have element width of 500 mm (edges 2 x 15 mm) and rolls 400 mm wide have element width of 370 mm (edges 2 x 15 mm). Level of quality required for laying surfacesThe laying surface must be suitably flat, with no juts, bumps or depressions. It can be a concrete surface or one from other construction materials that can support sufficient loads. The humidity of the laying surface may not exceed 2% (roughly 60% of relative humidity). It is necessary to prevent moisture penetrating the surface. Before starting work you must insulate against moisture. Thermal insulation is advisable, assuming the floor's profile permits it.
5. How to prepare the filmAlthough all Safe-t-FLEX elements are visually inspected at the factory before dispatch, the foil should be checked to ensure any rough handling has not damaged the Safe-t-FLEX element. Look for creasing or folds that could have been caused by a roll of element being trodden on. Any such damaged areas must be discarded. 6. Cutting the Element to size
7. How to insulate the ends of the film
8. Preparing to attach the connector clips to the heating filmElement layout drawings are not normally required for Safe-t-FLEX installations, thus enabling elements to be cut and fixed on site to accommodate last minute alterations to joist and floor layouts. Firstly check that the element identification printed on the clear edge selvedge complies with the grade and voltage required for the installation. For Australia unless otherwise stated on the Safe-t-FLEX Installation Test Certificate this will be 240 volts. 9. Checking the Crimping ToolBefore fixing the crimp connectors check that the Safe-t-FLEX Crimping tool is correctly adjusted to the required 1.25 - 1.40 m (50-55 thou.) gap when fully closed. If adjustment is required:
10. Attaching cold tails
Bare connecting leads and insert singly (doubled over) or in pairs into the cylindrical ferrule of the crimp connector. Cold tails from elements to thermostat positions must be securely clipped and positioned so that they cannot come into contact with any heated part of the element. Note: when a single cable is being crimped, bend the cable back to give the same volume of cable to crimped. Using the recommended "Safe-t-FLEX 234" pliers complete the crimp connection with the tool so that the "W" form of the tool is to the seamed side of the cylindrical female of the crimp.
Using only the Safe-t-FLEX 234 crimping pliers supplied attach metal crimp connectors to both copper conductors at one end of the element. Locate the crimp centrally on the end of the copper strip, then fold shut between thumb and forefinger. Fitting the crimp with the barrel to the same side as the copper electrode will assist locating the wiring harness. The crimping pliers are now utilized with 2 diagonal applications (firstly from the hinge side of the crimp, and then from the open side) to ensure that the whole area of the crimp in contact with the element is pressed flat. The ratchet mechanism on these pliers prevents the jaws being opened until the correct pressure has been applied. 11. Seal crimp connection pointsFinally, place 38 mm wide x 50 mm long mastic pads either side of the connection points. Carry this at least 30 mm down the connection wires. Knead the mastic round the cables and all contours. Make absolutely sure that a good effective seal is produced.Note: Normal pliers must not be used for this operation as crimps fitted incorrectly may overheat due to high contact resistance. 12. How to lay the film and connect it to the gridBefore laying the film, lay out a 3 mm closed cell foam underlay. In the places where you expect to place connection points, and in the places where conductors lead towards the electricity box, you need to make a groove for sinking them into the laying surface. Never lay the strips of film in such a way that their heating surfaces overlap. Lay elements with the copper strips facing upwards and locate in place using tape. Diagram showing a typical layout Insert the thermostat remote floor probe between 2 element strips as shown. Never step directly onto the foil during your work without a suitable layer to cushion against your weight. Heating film may never be placed in spots where dissipation of heat from the floor surface is restricted (low-lying furniture etc.). A fully qualified electrician should connect the connection cables into an already-prepared electrical box. Individual circuits should be planned to not exceed the 10-amp element rating therefore, the following limits would be:
No conductor should ever pass below the heating film itself. Since the cable is 4.5 mm thick, you must sink it at least 4 mm into the underlay or laying surface (into a groove) and fix it in place with tape. Once you have laid and connected all strips, check the resistance of the electrical circuits with an ohmmeter. If all the circuits are functioning right, lay clear polyethylene film at least 0.2 mm thick upon the whole floor surface. The individual strips must overlap by at least 20 cm. Pull them up by about 3 cm along walls. Alternatively, the moisture barrier supplied in the laminated floor supplier's kit, can be laid instead. The installation must be done so as to allow disconnection at all poles. 13. How to lay a floating floor.When laying a floor made up of individual segments, you must take special care not to damage the now-laid layers and the supply cable. Use a suitable subsurface. 14. Final measurements you should make.Measure individual circuit resistance once again with an ohmmeter. Record the measured data in a schematic drawing and archive it. Check the insulation resistance of the heating film. This should never fall below 0.5 maxwells. 15. Warranty conditionsThe manufacturer offers a warranty lasting 10 years from the date of sale for the functionality of Safe-t-FLEX floor heating element, provided that you observe the conditions lay out in this guide. Also, you must present an invoice and warranty sheet when making a claim. 16. Electrical considerationsThe wiring harness is made up using 1.5 mm2 cable. To satisfy the requirements of an acceptable standard, sheathed single core cable to BS.6004 would be acceptable. The manufacturers over many years have supplied a special double insulated flexible PVC cable, which experience has shown to be more acceptable for handling ability. Safe-t-FLEX heating elements are designed to accommodate a current carrying capacity of 10-amps. 17. Thermostat ControlOnly thermostats equipped with remote probes should be used to control temperatures in timber floor heating systems. WARNING temperature must be limited to 27 degrees Celsius to avoid altering moisture content in the timber floor. 18. Finally before leaving the site
Note: This installation guide is available in more detail in pdf format in our Downloads section. |
||